Maintenance Object Repair Procedure
Packet Interface Test (#598)
This non-destructive test checks the packet bus interface circuitry on the VAL
circuit pack. Test failure indicates faulty circuit pack.
Table 8-551. Test #598 Packet Interface Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
FAIL
Circuit pack has detected a failure of the Packet Interface test (#598).
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test continues to fail, replace the circuit pack.
PASS
The Packet Interface test (#598) passed.
Congestion Query Test (#600)
This non-destructive test queries the number of used buffers to determine
whether the VAL circuit pack is congested.
If:
Used buffers are, or are nearly,
exhausted,
The test fails,
Normal call handling resumes when the VAL circuit pack has recovered from
congestion.
8-1332
Issue 1 May 2002
Continued on next page
Then:
The test fails.
The switch alarms, and announcements
can fail.