Avaya S8700 Maintenance Manual page 383

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

TBRI-PT (ISDN Trunk-Side BRI Port)
Table 8-460. TBRI-PT Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
3073 (m)
Slip Query test
(#1244)
3585 (n)
Receive FIFO
Overflow (TDM
D-channel)
3586 (o)
3587 (p)
3588 (q)
46223
3589 (r)
3590 (s)
46211
3591 (t)
3592 (u)
3841 to
3942 (v)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
The far-end switch changed the ISDN service state. This may be a temporary condition.
Notes:
a. Loss of continuity of Layer 1 to the far end. It is assumed that Layer 1
remains active, even when both B channels are idle.
This test determines whether Layer 1 is active or not. If Layer 1 is not
active, the test attempts to activate it. If Layer 1 cannot be activated, the
port is taken out of service, and the test fails.
b. The D channel failed at Layer 2. Expiration of this timer indicates that
attempts to bring the failed link back into service have not succeeded and
some recovery actions should be taken on the associated B channels.
Upon expiration, associated in-service B channels are put in the
out-of-service/far-end state.
c. Error Type (513) — On-board hardware failure. The FIFO RAM buffers
have overflowed, indicating a hardware problem.
d. Error Type (514) — Transmit FIFO Overflow - This error indicates that the
circuit pack is having problems transmitting data to the TDM D channel.
This error only occurs only a system that switches the packet
implementation of the D channel over the TDM bus. This error indicates an
on-board problem related to the packet implementation of the D channel
(R6.2 and higher).
555-233-142
Alarm
On/Off
Level
Board
Test to Clear Value
MINOR
OFF
Log Only
ON
Continued on next page
Issue 1 May 2002
8-1079