XXX-BD (Common Port Circuit Pack)
Ringing Application Test (#51)
This test checks the ringing application circuitry common to every port on an
Analog Line circuit pack.
Table 8-576. Test #51 Ringing Application Circuit Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Could not allocate the necessary system resources to run test. The circuit pack
is not installed. Internal system error
2000
ABORT
There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error log, follow the
2. Run the busyout board, reset board, and release busy board
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if there are no problems
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
2. Retry the command at 1-minute intervals up to 5 times.
555-233-142
maintenance strategy that is recommended for this error type.
commands, and then retest.
found, replace the circuit pack.
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to Chapter 8, for a full
description of all possible states). You must wait until the port is idle before
retesting.