MAPD-BD (MAPD Interface Circuit Pack TN802)
3. At the command prompt, type ping 10.32.64.97 (the internal IP trunk
server's address), and press
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn:
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
b. Otherwise, replace the circuit pack.
4. At the command prompt, type ping 10.32.64.96 (the IP address of the
internal Motorola MPC860 processor), and press
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn:
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
b. Otherwise, replace the circuit pack.
5. Ping the gateway: at the command prompt, type ping XX.XXX.XXX.XXX
(the IP address of the gateway), and press
6. When finished, type exit at the command prompt, and press
555-233-142
Enter
and 6 in
Figure
8-18) have not worked loose.
and 6 in
Figure
8-18) have not worked loose.
.
bytes=32 time <##ms TTL=###
.
Enter
bytes=32 time <##ms TTL=###
.
Enter
Issue 1 May 2002
.
Enter
8-723