Avaya S8700 Maintenance Manual page 97

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

MMI-BD
Table 8-341. Test #1122/1123 MMI Synchronization Status Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
The MMI circuit pack is out of MMI synchronization. Run the long option of the
test board command.
1. Wait up to 5 minutes, and then reset the circuit pack with these commands:
2. Rerun the test; if the same result occurs again, replace the circuit pack.
1100
PASS
The MMI circuit pack is providing the synchronization correctly. This MMI
circuit pack is designated as the Master Sync source.
1101
PASS
The MMI circuit pack is listening to the synchronization signal correctly.
Control Channel Loop-Around Test (#52)
Refer to the repair procedure described in XXX-BD (Common Port Circuit Pack)
maintenance documentation as
page
8-1074.
SAKI Sanity Test (#53)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit
Pack) maintenance documentation as
555-233-142
busyout board UUCSS, then reset board UUCSS, followed by release
board UUCSS.
''Control Channel Loop-Around Test (#52)'' on
Continued on next page
''SAKI Sanity Test (#53)'' on page
Issue 1 May 2002
8-1074.
8-793

Advertisement

Table of Contents
loading

Table of Contents