SVC-SLOT (Service Slot)
Error Log Entries and Test to Clear Values
Table 8-446. Service Slot Error Log Entries
Error
Aux
Type
Data
600 (a)
Note:
a. Error type 600 indicates that an invalid circuit pack was inserted in slot 00,
the SERVICE slot, of a J58890BB port carrier. See the previous list of valid
circuit packs.
The invalid circuit pack's TN code can be displayed by using the list
configuration board UUCSS command — where UU is the cabinet
number, C is the carrier letter, and SS is the slot number (always 00) of the
alarmed circuit pack.
To retire the alarm, remove the invalid circuit pack.
555-233-142
Alarm
Associated Test
Level
None
MINOR
On/Off
Board
Test to Clear Value
ON