Maintenance Object Repair Procedure
MET Line Station Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status
record contained in the processor. The lamp updates run only if the station is
in-service.
Table 8-333. Test #60 MET Line Station Lamp Updates Test
Error
Test
Code
Result
Description / Recommendation
1
ABORT
This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
3
ABORT
Station is in ready-for-service or out-of-service state. This may be due to wiring
or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
2. If the port status is idle, then retry the command at 1-minute intervals up to
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
MET Line Station Lamp Updates completed successfully.
1. If complaints persist, investigate by using other circuit pack tests, and by
8-778
Issue 1 May 2002
error type is present, then release the port via the release station
<extension> command and run the test again.
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
5 times.
examining the station, wiring, and connections.
Continued on next page
555-233-142

Advertisement

Table of Contents
loading

Table of Contents