Maintenance Object Repair Procedure
Table 8-365. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
Any
FAIL
The test failed. This can be due to on-board or off-board problems. Off-board
problems of concern include RMC-ENV faults, TDM-BUS faults, and faults
associated with the tone detectors/tone generators. Clear every off-board
problem before replacing the board. Keep in mind that a TDM-BUS problem is
usually the result of a faulty board connected to the backplane or bent pins on
the backplane.
1. Resolve any TONE-BD and/or TONE-PT errors.
2. Retest when the faults from step 1 are cleared.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and by examining station,
trunk, or external wiring.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
8-860
Issue 1 May 2002
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Continued on next page
555-233-142