TBRI-BD (TN2185 ISDN Trunk-Side BRI)
Table 8-458. TBRI-BD Error Log Entries — Continued
Error
Aux
Type
Data
3330 (j)
46083
3586 (k)
3840 (l)
4096
to
4101
3842 (m)
46095
3843 (n)
46097
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. The circuit pack stopped functioning or is physically removed from the
system.
If the circuit pack is not in the system, insert a circuit pack in the same slot
as the error indicates. See note (g).
b. Transient communication problems between the switch and this circuit
pack. Execute the test board UUCSS command and refer to the repair
procedures for the
8-1350.
c. On-board hardware failure. Aux data values correspond to the following
detected errors:
4352
4353
4355
4357
Reset the circuit pack with the busyout board UUCSS and reset board
UUCSS commands. When reset, the circuit pack executes a set of tests to
detect the presence of any of the faults listed above. Detection of one of
these errors during initialization causes the circuit pack to lock-up and
appear insane to the system. See the repair procedure in Note (a).
555-233-142
Associated Test
NOTE:
This alarm logs approximately 11 minutes after removing the circuit
pack and/or the SAKI Sanity test (#53) fails.
''Control Channel Loop-Around Test (#52)'' on page
External RAM error
Internal RAM error
ROM Checksum error
Instruction set error
Alarm
On/Off
Level
Board
Test to Clear Value
MINOR
OFF
MINOR
OFF
Continued on next page
Issue 1 May 2002
8-1071