Maintenance Object Repair Procedure
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk's translation is correct. Translation
updates include the following data: line type, dial type, timing parameters, and
signaling bits enabled. The port audit operation verifies the consistency of the
current state of the trunk as kept in the DS1 Interface circuit pack and in the switch
software.
Table 8-367. Test #36 Audit and Update Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
The test was aborted because system resources required to run this test were
not available. The port may be busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1006
ABORT
The test was aborted because the station is out of service. This condition may
be accompanied by an error type 18 entry in the error log. You may want to
determine why the station was taken out of service. (When stations are taken
out of service by maintenance software, the problems that preceded that point
must be cleared.)
1. Use the status station command to check the service state of the port. If
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 or 8
FAIL
Test failed due to internal system error. Do not replace port board.
1. Retry the command at 1-minute intervals up to 5 times.
8-864
Issue 1 May 2002
extension of the port. Use the status station command to determine the
service state of the port. If the service state indicates that the port is in
use, then the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
the port is indeed out of service, enter the release station command to
bring the station back into service.
Error code 7: the failure occurred during station translation download (to
DS1 Interface circuit pack).
Error code 8: the failure occurred during station ringer update.