MEDPRO (Media Processor MAPD Circuit Pack)
Table 8-320. Test #1381 NT Reset Test — Continued
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
System resources required for this test are not available.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
PASS
The circuit pack initializes correctly.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
555-233-142
1. Retry the reset board UUCSS command at 1-minute intervals up to 5
times.
1. Execute the reset board UUCSS command again.
2. If the problem persists, replace the circuit pack.
1. Run the short test sequence.
1. Ensure that the board translations are correct. Administer the
MEDPROMEDPRO interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board re-initializes it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
Continued on next page
Issue 1 May 2002
8-753