PDATA-PT (Packet Data Line Port)
Table 8-373. Test #602 PDATA Port Local Loop-Around Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
The port is in use for a call. Use status data-module extension command to
determine when the port is available for testing.
1. Retry the command when the port is idle. The port can be made idle by
1006
ABORT
Port is out-of-service.
1. Run status data-module extension to check if the port is busied out. Run
2. See the PKT-BUS MO's section, and fix any problems that are related to
2000
ABORT
Response to the test was not received for the PDATA circuit pack within the
allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2. reset board UUCSS if the other ports on the board are idle (amber LED is
3. Retry the command at 1-minute intervals up to 3 times.
4. Replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The PDATA circuit pack has detected a failure in the execution of the test.
1. If the test fails 3 times, reset board UUCSS if the other ports on the board
2. If the test fails again, replace the circuit pack.
PASS
The PDATA on-board loop-around test for the port has passed verifying the
integrity of the per-port circuitry.
555-233-142
executing the busyout port UUCSSpp command. This command is
destructive causing every call and link associated with the port to be torn
down.
release port UUCSS to free it, re-run the test.
the packet bus.
off), or run the status data-module extension command.
are idle (amber LED is off), or run the status data-module extension
command.
Continued on next page
Issue 1 May 2002
8-881

Advertisement