Maintenance Object Repair Procedure
Hardware Error Log Entries and Test to Clear
Values
Table 8-399. PMS Link Maintenance Error Log Entries
Error
Type
Aux Data
1
0
0
18 (a)
0
257 (b)
Any
513 (c)
Any
769 (d)
Any
1025 (e)
40–49
1281 (f)
10–19
1537 (g)
N0–N9
1793 (h)
Any
2049 (i)
Any
2305 (j)
50–59
2561 (k)
Any
2817 (l)
100–109
200–209
300–309
3073 (m)
70–79
3841 (n)
20–29
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be down graded to Warning alarms based o the value in the set options
command.
Notes:
a. The PMS Link has been busied out with the busyout pms-link command.
The link is torn down. Enter the release pms-link command to restore the
link.
b. The Link Retry test (#215) fails. An error was detected when setting up the
link. Refer to the Procedures for Restoring the PMS Link above.
8-952
Issue 1 May 2002
Associated Test
Any
busyout pms-link
Link Retry test (#215)
None
None
None
None
None
None
None
None
None
None
None
None
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
MINOR
OFF
2
WARNING
Test to Clear Value
test pms sh r 1
release pms-link
test pms-link l
test pms-link
test pms-link
release pms-link, or
test pms-link
test pms-link
555-233-142