Maintenance Object Repair Procedure
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external PMS
device. If the link has been disconnected already, then this test just returns
"PASS." Every resource allocated for a PMS Link is released after this test.
Table 8-400. Test #213 Link Tear Down Test
Error
Test
Code
Result
Description / Recommendation
40
ABORT
Internal system error.
50
1. Retry the command at 1-minute intervals up to 5 times.
1010
ABORT
The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
2. Retry test pms long command to execute the test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The PMS Link is torn down.