Avaya S8700 Maintenance Manual page 662

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
VC Port Reset DSP Test (#1106)
This test is destructive.
This test resets the VC-DSPPT and the DSP associated with it. As part of the
reset procedure, the VC-DSPPT will execute a series of self-tests on the
hardware. If these self-tests fail, the test will fail; otherwise the test will pass.
Before executing the test, the VC-DSPPT must be busied out by executing the
busy port UUCSSpp command. After the completion of the test, the VC-DSPPT
must be released by executing the release port UUCSSpp command.
Table 8-564. Test #1106 VC Port Reset DSP Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available, or the port may be
busy with a call.
1. Retry the command at 1-minute intervals up to 5 times.
1015
ABORT
The VC-DSPPT is not busied out.
1. Busyout the VC-DSPPT by executing the busy port UUCSSpp command,
2000
ABORT
Response to the test was not received from the VC-DSPPT within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The reset of the VC-DSPPT was unsuccessful.
1. Replace circuit pack.
PASS
The VC-DSPPT was successfully reset.
1. Release the VC-DSPPT by executing the reset port UUCSSpp command.
8-1358
Issue 1 May 2002
and then retry the test.
Continued on next page
555-233-142

Advertisement

Table of Contents
loading

Table of Contents