MIS (Management Information System)
MIS (Management Information
System)
MO's Name
Alarm
(in Alarm Log)
Level
MIS
WARNING
The Management Information System (MIS)/Call Management System (CMS) MO
is used only to monitor MIS busyouts during administration of MIS translations.
There are no hardware failures associated with this MO.
The MIS/CMS is an adjunct processor that collects Automatic Call Distribution
(ACD) data sent from the switch. In order to change MIS translations, a switch
administrator must first enter a busyout mis command at the G3-MT. When the
MIS is busied out, the switch will stop sending ACD data to the MIS, and a
Warning alarm will be raised.
When the switch administrator is finished, a release mis command should be
entered at the terminal. This will clear the Warning alarm and allow the switch to
send ACD data to the MIS.
Error Log Entries and Test to Clear Values
Table 8-336. Management Information System Error Log Entries
Error
Aux
Type
Data
1
0
0
2
18
0
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test's description, and follow its recommended procedures.
2.
When the busyout MIS command is issued, no data is sent to the MIS/CMS regardless of the link state.
To allow data to be sent to MIS/CMS, a release mis command must be issued from the terminal.
555-233-142
Initial Command to Run
release mis
Associated Test
Alarm Level
Any
Any
busyout mis
WARNING
Full Name of MO
Management Information System
On/Off
Test to Clear
Board
Value
Any
release mis
ON
release mis
Issue 1 May 2002