Avaya S8700 Maintenance Manual page 150

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-360. Test #565 Digital Port Sanity Test — Continued
Error
Test
Code
Result
Description / Recommendation
50
FAIL
The switch was unable to communicate with the port circuitry used for digital
trunk testing.
100
FAIL
Data was not sent from port 2 to port 3 successfully in asynchronous mode.
101
FAIL
Data was not sent from port 3 to port 2 successfully in asynchronous mode.
102
FAIL
Data was not sent from port 2 to port 3 successfully in synchronous mode.
103
FAIL
Data was not sent from port 3 to port 2 successfully in synchronous mode.
1. Reset the circuit pack via the busyout board UUCSS, reset board
2. Test the port again via the test port UUCSS02 l command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test digital port digital trunk testing capability is operating
correctly.
8-846
Issue 1 May 2002
UUCSS, release board UUCSS command sequence.
Continued on next page
555-233-142