OPS-LINE (DS1 Off-Premises Station Line)
Error Log Entries and Test to Clear Values
Table 8-364. DS1 OPS Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
15(a)
Any
Audit and Update test
(#36)
18(b)
0
busyout station <ext>
130(c)
None
1281
Conference Circuit test
(#7)
1537
NPE Crosstalk test (#6)
1793(d)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors (if any).
b. The DS1 OPS Line has been busied out by a busyout station <ext>
command. No calls can be made on this line.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interface circuit pack.
Since there is no error against the OPS-LINE port, no alarm is raised
against the OPS-LINE port. However, there should be errors logged
against the DS1 Interface circuit pack. Look for DS1-BD/UDS1-BD errors
in the Hardware Error Log, and follow the appropriate procedures provided
in the
555-233-142
Alarm
Level
Any
WARNING
WARNING
MINOR
MINOR
''DS1-BD (DS1 Interface Circuit Pack)'' on page
On/Off
Board
Test to Clear Value
Any
test station <ext>
OFF
release station <ext>
ON
test station <ext>
ON
test station <ext> l r 4
ON
test station <ext> l r 3
test board UUCSS l
8-456.