MET-LINE (MET Line)
Table 8-332. Test #57 Hybrid Circuit and Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2012
ABORT
Internal system error.
2103
ABORT
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
555-233-142
repeat test at 1-minute intervals up to 5 times.
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.