TONE-BD (Tone-Clock Circuit Pack)

TONE-BD (Tone-Clock Circuit Pack)
MO's Name (in
Alarm Log)
Alarm Level
TONE-BD
MAJOR
TONE-BD
MINOR
TONE-BD
WARNING
1.
UU is the universal cabinet number (1–64). C is the carrier designation (A, B, C, or D).
The TONE-BD MO supports EPNs in an S8700 Media Server system using a
TN2312 IP Server Interface (IPSI) circuit pack
The TONE-BD MO consists of a module located on the IPSI circuit pack and
provides tone generation, tone detection, call classification, clock generation, and
synchronization.
The TN2312 IPSI circuit pack contains two independent components:
Tone Generator that provides every tone needed by the system
Clock that generates the system clocks for both the Time Division Multiplex
(TDM) bus and the packet (LAN) bus
It also aids in monitoring and selecting internal synchronization references.
When resolving an IPSI circuit pack's errors/alarms, the following sections should
also be consulted:
Use the set ipserver-interface command to establish the tone and
synchronization resources for the system.
TONE-PT (Tone Generator)
TDM-CLK (TDM Bus Clock)
SYNC (Synchronization)
ETR-PT
PKTINT (IPSI only)
If more tone-detection resources are needed, the additional resources must be
provided by TN748, TN420, or TN744 circuit packs.
555-233-142
1
Initial Command to Run
test tone-clock UUC short
test tone-clock UUC short
release tone-clock UUC
Full Name of MO
Tone-Clock circuit pack
Tone-Clock circuit pack
Tone-Clock circuit pack
Issue 1 May 2002
8-1173