Avaya S8700 Maintenance Manual page 594

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-538. Test #1212 CPE Loop-Back Jack Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS cpe-loopback-jack-test-begin
1005
ABORT
CPE Loop-Back Jack test cannot be executed in the current configuration. To
run this test, the TN464F or later suffix UDS1 must be administered for
24-channel operation. The "Bit Rate" field on the DS1 circuit pack
administration form must be set to "1.544" for 24-channel operation.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
2. Retry the command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the IPSI circuit pack via
the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950
ABORT
Another loopback/span test is already executing on the DS1 board or the board
is in a network-requested loop-back mode (line loopback or payload loopback).
The hardware error log will indicate whether a Customer Loop-Back Jack test,
Far CSU Loopback test, or the One-Way Span test is executing or if the board
is in line-loopback or payload-loop-back mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a loopback/span test
is already active, that test must be terminated using the test ds1-loop UUCSS
end-loopback/span-test command in order to execute this test.
8-1290
Issue 1 May 2002
command at 1-minute intervals up to 5 times.
the UDS1 Interface circuit pack into the out-of-service state.
Continued on next page
555-233-142

Advertisement

Table of Contents
loading

Table of Contents