Avaya S8700 Maintenance Manual page 652

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-559. VC-BD Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
1025 (f)
4363
NPE Audit test (#50)
1281 (g)
Any
SAKI Sanity test (#53)
1293 to
46088
SAKI Sanity test (#53)
1294 (h)
to
46096
1538 (i)
46082
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. The circuit pack stopped functioning or it was removed from the system.
This alarm is logged approximately 11 minutes after the circuit pack is
removed and/or the SAKI Sanity test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error
indicates, if the circuit pack is not already in the system. Or, if the circuit
pack is in the system and the red LED is on, then follow instructions for
Red alarms.
!
b. This circuit pack is busied out by the busyout board UUCSS command.
c. Transient communication problems exist between the switch and this
circuit pack. Execute the test board UUCSS command and see the repair
procedures for the
8-1350.
d. The circuit pack detected an on-board hardware failure. The reported aux
data values correspond to the following detected errors:
Error
4352
4353
4355
4357
8-1348
Issue 1 May 2002
Alarm
Level
MAJOR
MINOR
MINOR
CAUTION:
If the TN788 Voice Conditioner circuit pack (VC-BD) is not Vintage 2
or later, it must be replaced.
''Control Channel Loop-Around Test (#52)'' on page
Description
External RAM error
Internal RAM error
ROM Checksum error
Instruction set error
On/Off
Board
Test to Clear Value
ON
ON
ON
Continued on next page
555-233-142

Advertisement

Table of Contents
loading