Maintenance Object Repair Procedure
Table 8-391. Test #572 Maintenance/Test Circuit Pack Query Test — Continued
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
Maintenance could not allocate every necessary system resource to perform
this test.
2500
ABORT
An internal operation failed; the test could not be completed.
1. Re-enter the command at 1-minute intervals up to 5 times.
FAIL
The Maintenance/Test packet bus port has detected faults on the Packet Bus.
The error codes are interpreted as follows:
2xxx
The Maintenance/Test packet bus port is unable to correct every Packet Bus
fault it has detected.
x0xx
None of the packet bus faults are open faults.
x1xx
At least some of the packet bus faults are open faults. Look for error type 2305
in the Error Log. The Aux Data value indicates the number of open leads.
xxyy
The last two digits of the error code indicate the total number of faulty packet
bus leads detected.
1. See the
PASS
No faults have been detected on the packet bus by the Maintenance/Test
circuit pack. This is an indication that the packet bus is operating correctly.
8-924
Issue 1 May 2002
Examples:
Error Code 2003 FAIL: The Maintenance/Test packet bus port has
detected 3 faulty leads. None of them are opens. At least one was unable
to be corrected.
Error Code 1103 FAIL: The Maintenance/Test Packet Port has detected 3
faulty leads. At least one is an open. The Maintenance/Test circuit pack
was able to correct all of them by reconfiguring.
''Isolating and Repairing Packet-Bus Faults''
''Alarms, Errors, and Troubleshooting''
section in
Chapter 4,
Continued on next page