Avaya S8700 Maintenance Manual page 318

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
fndpremv LJK 102600
Figure 8-38. Fan Removal
Hardware Error Log Entries and Test to Clear
Values
Table 8-433. Cabinet sensors error log entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1(a)
Any
Cabinet Temperature or
Voltage Query test (#122)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to the appropriate
test's description, and follow the recommended procedures.
Notes:
a. Error Type: 1 – The power-/fan-status lead indicates that an RMC
cabinet's power supply has detected an alarm condition. The condition can
be caused by the failure of any fan's or any power supply's output. If more
than one RMC cabinet exists, every power-/fan-status lead is tied together.
8-1014
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test environment
MAJOR
ON
test environment
555-233-142