Avaya S8700 Maintenance Manual page 288

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
RANL-STA (Remote Analog Line
(Station) Port
MO's Name (in
Alarm Log)
RANL-STA
RANL-STA
1.
UU is the universal cabinet number (1–64). C is the carrier designation (A, B, C, or D). SS is the
number of the slot where the circuit pack resides (01–10). pp is the 2-digit port number (01, 02,...).
A per-port instance of this MO (RANL-STA) is used to maintain the circuitry
associated with a port which has been translated as analog station. The combo
blade circuit board has the capability of having two instances of this type of MO.
Failures of the neon message waiting lamp power and the common ringing
application circuitry are reported as part of common port circuit pack errors; see
errors 1281 and 1793 in
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the Tests field of the change station extension form. Be aware that
this action will also disable Test 35 on that station.
8-984
Issue 1 May 2002
Initial Command to
1
Alarm Level
Run
MINOR
test port UUCSSpp l
WARNING
test port UUCSSpp sh
''XXX-BD (Common Port Circuit Pack)'' on page
Full Name of MO
Remote Analog Line
Port
Remote Analog Line
Port
8-1374.
555-233-142

Advertisement

Table of Contents
loading

Table of Contents