Avaya S8700 Maintenance Manual page 358

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
The status sys-link location command shows the state of both the hardware
paths (current and faulted) along with the state of each of the components in the
hardware path. When analyzing any system link problem:
1. Look for alarms on the components listed under desired hardware path.
2. If any alarms are present, then follow the maintenance procedures for the
alarmed components to clear those alarms first.
3. When every component is alarm free, wait for 3 minutes to allow the links
to recover.
4. Test the system link (test sys-link PCSSpp long clear), and notice any
tests that fail.
5. If there are any failures, fix the problems indicated by the tests and repeat
the procedure.
Error Log Entries and Test to Clear Values
Table 8-451. Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
13 (a)
System Link Status
(#985)
257 (b)
513 (c)
772 (d)
1025 (e)
1281 (f)
1537 (g)
1793 (h)
8-1054
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
MINOR
OFF
WARNING
WARNING
OFF
test sys-link UUCSSpp l cl
WARNING
OFF
test sys-link UUCSSpp l cl
WARNING
OFF
test sys-link UUCSSpp l cl
WARNING
OFF
test sys-link UUCSSpp l cl
WARNING
OFF
test sys-link UUCSSpp l cl
WARNING
OFF
test sys-link UUCSSpp l cl
WARNING
OFF
test sys-link UUCSSpp l cl
555-233-142