Maintenance Object Repair Procedure

Circuit Pack Restart Test (#594)

NOTE:
This test is destructive.
Execute this test (not part of either short or long demand test sequence) to reset
the circuit pack only if there are PPCPU errors. This test fails if the circuit pack
does not return to a sane state after being reset. The circuit pack resets through
the SAKI Sanity test (#53).
Table 8-547. Test #594 Circuit Pack Restart Test
Error
Test
Code
Result
Description / Recommendation
None
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1015
ABORT
Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Retry the command at 1-minute intervals up to 5 times.
3. If the problem persists, escalate the problem.
1966
ABORT
The board is in the process of running the autosave command to save
announcements.
1. Retry the command again later.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1, 2
FAIL
The circuit pack failed to reset.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, pull out and reseat the circuit pack.
3. If the problem persists, replace the circuit pack.
PASS
The circuit pack initialized correctly.