Avaya S8700 Maintenance Manual page 126

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-351. M/T-ANL Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
(a)
0
Any
1 (b)
41018
none
18
0
busyout port UUCSSpp
257
Any
NPE Crosstalk test (#9)
513
Any
Analog Port Sanity test
(#963)
769
Any
Analog Port Digital
Loop-around test (#13)
3840(c)
Any
Hook State Inquiry test
(#566)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has
been removed since the Error Log was last cleared. Verify that the circuit
pack has been reinserted.
b. This error indicates a hardware failure on the Analog Port circuitry.
Replace the Maintenance/Test circuit pack if the above command does not
resolve the alarm.
c. This error indicates that call processing records did not agree with
on-board records for the hook state (on-/off-hook) of the Maintenance/Test
analog port. This error is not service-affecting and no action is required.
8-822
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test port UUCSSpp
MINOR
ON
test port UUCSSpp l r 3
WARNING
OFF
release port UUCSSpp
MINOR
ON
test port UUCSSpp l r 3
MINOR
ON
test port UUCSS01 r 2
MINOR
ON
test port UUCSSpp r 3
555-233-142

Advertisement

Table of Contents
loading

Table of Contents