Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-501. Tone-Clock Circuit Pack Error Log Entries
Error
Type
Aux Data Associated Test
1
0
0
Any
1 (a)
0
Circuit pack removed or
SAKI Sanity test (#53)
23 (b)
0
None
125 (c)
None
126 (d)
None
257 (e)
65535
Control Channel test
(#52)
257 (e)
Any
None
513 (f)
Any
None
769 (g)
4358
None
1025 (h)
4363
NPE Audit test (50)
1538 (i)
Any
None
2049 (j)
0
Clock Health Inquiry
test (#46)
2305 (j)
0
Clock Health Inquiry
test (#46)
2561 (k)
Any
None
3329 (l)
0
None
3840 (m)
Any
None
3848 (n)
0
Clock Health Inquiry
test (#46)
3856 (o)
3857,
NONE
3858 (p)
3872 (q)
0
None
3999 (r)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
3.
Use the command set ipserver-interface.
8-1180
Issue 1 May 2002
On/Off
Alarm Level
Board
Any
Any
MINOR
ON
WARNING
OFF
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
MAJOR
ON
MAJOR
ON
MAJOR
ON
MINOR/
OFF
2
WARNING
MAJOR
ON
MAJOR
ON
Test to Clear Value
test tone-clock PC sh
test tone-clock PC r 20
test tone-clock PC sh
set tone-clock UC
3
override
set tone-clock UC
3
override
set tone-clock UC
3
override
set tone-clock UC
3
override
set tone-clock UC
3
override
busyout/release
ipserver-interface
set tone-clock UC
3
override
555-233-142