Maintenance Object Repair Procedure
NIC Query Test (#1383)
This test is nondestructive.
This test passes if the Ethernet port is connected, and you can talk on the
network. Otherwise, it fails with no fail code or AUX data.
Table 8-321. Test #1383 NIC Query Test
Error
Test
Code
Result
Description / Recommendation
None
ABORT
System resources required for this test are not available.
1015
ABORT
Port is not out-of-service.
2100
ABORT
System resources required for this test are not available.
FAIL
The Ethernet port is not connected, and you cannot talk on the network.
PASS
The Ethernet port is connected, and you can talk on the network.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
8-754
Issue 1 May 2002
1. Retry the command at 1-minute intervals up to 5 times.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the command again.
1. Retry the command at 1-minute intervals up to 5 times.
1. Ensure that the board translations are correct. Administer the MedPro
interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board re-initializes it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
Continued on next page