Maintenance Object Repair Procedure
n. Reorder message. The trunk could not be seized. This error causes the
Tie Trunk Seizure test (#73) to run and is considered a problem only if that
test fails, logging error 1793. In this case, the trunk may be placed in the
ready-for-service state, allowing only incoming calls. This service state
shows up as disconnected on the trunk status screen. Run the Tie
Trunk Seizure test, and follow recommended procedures.
TN439 logs aux data 57424 or 50944. Other circuit packs log 50944. This
error is associated with Test #747 for TN439, Test #73 for TN497, and no
test for the others.
o. These errors apply only to TN497.
p. Retry Failure error. This error is logged only. It is not a hardware failure
and hence does not start any testing or generate any alarms. This error
comes from call processing and is generated when a second attempt
(retry) to seize an outgoing trunk fails.
q. Glare error. This error is logged only. It is not a hardware failure and
hence does not start any testing or generate any alarms. This error is the
result of a simultaneous seizure of a 2-way trunk from both the near and
the far ends. Attempt to place the call again. If the error persists, execute
the Tie Trunk Seizure test (#73), and follow its outlined procedures.
r. Error 3841 indicates that test calls made by the Automatic Transmission
Measurement System (ATMS) returned measurements in the
unacceptable range. Error 3840 indicates measurements were in the
marginal range. Use list testcall detail to examine the specific
transmission parameters which are out of spec, and investigate the trunk
for that kind of noise. If the noise is acceptable, then the AMTS thresholds
administered on page 4 of the trunk group form should be changed.