Maintenance Object Repair Procedure
For TN439, Test #747 is run instead of #73. This test seizes a trunk and
outpulses a pause digit. This test aborts on ports administered as access
endpoints.
Table 8-496. Test #73,#747 Tie Trunk Seizure Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The trunk may be
busy with a valid call. Use the display trunk xx to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the
2. If the port status is idle, then retry the command at 1-minute intervals up to
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the port.
If the service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
This test is not valid for this trunk translation. Must be a wink-start or delay dial
trunk and must be outgoing or 2-way for this test to run. For the TN2140, the
trunk must also be continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this abort
1018
ABORT
Test disabled via administration.
1. Verify that the "Maintenance Tests?" field on the Trunk Group Form is set
1040
ABORT
This test is not performed for trunk ports administered as access endpoints.
1. Verify this port is an access endpoint by using the display port command.
2. If the port has been administered as an access endpoint, then this test
8-1164
Issue 1 May 2002
Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up. The far-end PBX
may not be releasing.
5 times.
message should be ignored.
to "n". To enable the test, issue the change trunk-group x command
where "x" equals the number of the trunk group to be tested. Then change
the entry in the "Maintenance Tests?" field on the form to "y."
should abort.