Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-512. TTR Level Error Log Entries
Error
Aux
Type
Data
1 (a)
1
2 (b)
2
3 (c)
3
4 (d)
4
5 (e)
5
6 (f)
6
7 (g)
7
8 (h)
8
9 (i)
9
!
WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12
(France).
Notes:
a. Error code 1 does not indicate a current error condition. It indicates that
the number of DTMR ports in service was below the administered
threshold, but is now equal to or greater than the threshold. These errors
are typically generated during boot time or other transitional states when
the ports are being brought into service.
b. The total number of DTMR ports currently in service is below the
administered threshold. To clear the alarm, see
TTR-LEV'' on page
c. Error code 3 does not indicate a current error condition. It indicates that
the number of GPTD ports in service was below the administered
threshold, but is now equal to or greater than the threshold. These errors
are typically generated during boot time or other transitional states when
the ports are being brought into service.
d. The total number of GPTD ports currently in service is below the
administered threshold. To clear the alarm, see
TTR-LEV'' on page
8-1206
Issue 1 May 2002
Associated Test
Alarm Level
None
WARNING
(See WARNING
message below)
None
WARNING
None
WARNING
MAJOR
MINOR
MINOR
8-1205.
8-1205.
On/Off
Board
Test to Clear Value
OFF
OFF
OFF
OFF
OFF
OFF
''Repair Procedure for
''Repair Procedure for
555-233-142