Avaya S8700 Maintenance Manual page 244

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-395. Test #885 Private Loop-Around Tests
Error
Test
Code
Result
Description / Recommendation
1006,
ABORT
Packet Interface circuit is out of service, so normal maintenance tests do not
1137
run on that circuit.
1. Enter reset packet-interface Uc to reset the Packet Interface circuit.
1334
ABORT
The Packet Interface circuit's command queue is full. This should be a
temporary condition caused by a high rate of commands being sent to a Packet
Interface circuit. Continued operation with a full command queue will cause a
system WARM restart that may escalate to more severe restart levels.
1. Retry the command at 10-second intervals up to 5 times.
1335
ABORT
Internal IPSI error. The Packet Interface circuit is on the standby IPSI, so this
test is not allowed to execute.
1. To run this test on the standby Packet Interface, enter set
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
The IPSI circuit pack's Packet Interface is assigned, but is not detected as
BOARD
being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312 IPSI circuit pack in the assigned slot, and rerun the
8-940
Issue 1 May 2002
For further action, see the procedures in
Packet Interface Reset test (#889).
ipserver-interface Uc to activate it.
test.
Table 8-394 on page 8-938
Continued on next page