SYSTEM (System)
Notes for SYSTEM Error 605 AUX Data:
1. Follow repair instructions in "STBY-SPE" for the particular standby server
problem. After fixing that problem, try the interchange again.
2. Mass Storage System is in use. Check Disk and Removable Media LEDs
for activity. Wait until every MSS activity completes, then retry the
interchange again. If the problem persists, check for alarms and errors
against MSS components and follow the repair procedures for the "MSS"
MO.
3. Test the PKT-INT on both carriers with the long test sequence. Follow
procedures for "PKT-INT". Once every test of both PKT-INTs passes, try
the interchange again.
4. Consult SW-CTL service documentation. Test SW-CTL on both carriers
with the long test sequence. Follow repair instructions for any failures.
Once every test of both SW-CTLs passes, try the interchange again.
5. Make sure the standby server is refreshed, then try the interchange again.
6. Examine alarm log to determine which of the PKT-INT or SYSAM circuit
packs has a minor alarm against it. Consult the section in this chapter for
that circuit pack.
7. Run test duplication-interface long, and follow instructions for any test
that does not pass.
555-233-142