Avaya S8700 Maintenance Manual page 466

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-494. Test #33 Looparound and Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
7,
FAIL
129,
(cont'd)
131, or
133
(cont'd)
PASS
Tie trunk Looparound and Conference test is successful. This port is
functioning properly.
1. If users are reporting troubles, examine loop connections to the port.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Verify that the board's translations are correct. Translate the board, if
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
Audit Update Test (#36)
This test sends to the circuit pack updates of translations for every administered
port on the circuit pack. It is non-disruptive and guards against possible
corruption of translation data contained on the circuit pack. No response is
expected from the circuit pack. Port translation data includes:
Start type: immediate, automatic, wink-start, or delay dial
Rotary or DTMF senderization in or out
Disconnect timing: 10 to 2550 ms in 10-ms increments
DMTF time slot
Continuous-seize-ack? (TN2140)
8-1162
Issue 1 May 2002
NOTE:
If the loop-around and conference circuit test fails for every port on a
circuit pack, a -5 Volt power problem is indicated. If a TN736 or TN752
power unit circuit pack is present, the power unit may be defective. To
investigate problems with a power unit, see the RMC-ENV MO. If a red
LED on TN736 or TN752 power unit circuit pack is on, replace the pack.
If the test fails on more than 1 port, check for errors on the TONE-BD or
the TONE-PT. If errors, take appropriate actions. When the tone errors
are cleared, rerun the test. If the test fails again, see FAULT
ISOLATION in this table above.
necessary.
between the internal ID and the port.
Continued on next page
555-233-142

Advertisement

Table of Contents
loading

Table of Contents