Maintenance Object Repair Procedure
Tie Trunk EPF Test (#74)
The first part of this test checks for proper activation and deactivation of the port's
E lead. The second part checks the M lead electronic power feed current flow.
Table 8-497. Test #74 Tie Trunk EPF Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run the test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The trunk may be
busy with a valid call. Use the display trunk xx to determine trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the
2. If the port status is idle, then retry the command at 1-minute intervals up to
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the port.
If the service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
This test is not valid for this trunk translation. Must be a type-1 standard trunk
for this test to run.
1. Check trunk configuration. If it is not a type-1 standard trunk, this abort
1014
ABORT
The test was aborted because the circuit pack has not been inserted into the
system.
1. Use the list configuration board command to make sure the circuit pack
2. If the board is not inserted, make sure the circuit pack is inserted in the
8-1166
Issue 1 May 2002
Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up. The far-end PBX
may not be releasing.
5 times.
message should be ignored.
is inserted in the carrier.
carrier and fully seated.
Continued on next page