Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-377. PDMODULE, TDMODULE Error Log Entries
Error
Aux
Type
Data
Associated Test
0 (a)
0
None
1 (b,n)
40987
None
1 (c,n)
1 – 20
None
15 (d)
Any
None
18 (e)
0
busyout port UUCSSpp
257 (f)
40971
None
513
0
Data Module audits
(#17)
769 (g,n)
40988
None
1281
Any
Data Module audits
(#17)
1537 (h,n)
40968
None
1793
Information Channel
and Control Channel
Looparound (#13)
2049
NPE Crosstalk (#9)
2304 (i)
None
2305 (j)
32770
None
2305 (k)
40967
None
2561 (l)
Any
Data Module Internal
Looparound (#175)
2817 (m)
Link GPP Loop (#183)
Against Links
3841 (n)
NONE
3841 (o)
None
8-888
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
WARNING
OFF
WARNING
OFF
WARNING
OFF
release port UUCSSpp
WARNING
OFF
test port UUCSSpp sh r 6
WARNING
OFF
WARNING
OFF
test port UUCSSpp sh r 4
WARNING
OFF
MINOR
ON
test port UUCSSpp l r 3
MINOR
ON
test port UUCSSpp l r 3
WARNING
OFF
test port UUCSSpp l r 5
MAJOR
ON
555-233-142