Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-479. TDM Bus Clock Error Log Entries
Error
Aux
Type
Data
Associated Test
2
0
0
Any
1 (a)
0
None
130 (b)
None
513 (c)
Any
Clock Circuit Status inquiry
(#148)
769 (d)
Any
Clock Circuit Status inquiry
(#148)
1025 (e)
Any
Clock Slip inquiry(#149)
1281,
Any
None
1282 (f)
1537
Any
Clock PPM inquiry (#150)
2305 (g)
0
None
1.
As a general rule, any on-board errors against the TDM Bus Clock should be resolved before pursuing any other
errors against PNC components. Off-board clock errors may be caused by other board errors, and should
usually be addressed once any on-board errors have been resolved.
2.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
3.
Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values used in
the set options command.
Notes:
a. The IPSI circuit pack may have a clock at the edge of its specified
frequency.
1. Replace the IPSI circuit pack identified in the error log. See
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. The tone-clock has reported an out-of-lock condition. A aux value of 1
indicates this error is an out-of-lock with the primary reference. A aux
value of 2 indicates this error is an out-of-lock with the secondary
reference. It could not lock onto the frequency of that synchronization
reference. This will lead to a change in the synchronization reference if the
condition continues.
8-1124
Issue 1 May 2002
Alarm
Level
Any
MINOR
MINOR
MAJOR
MINOR
WARNING OFF
''Replacing the IPSI Circuit Pack'' on page
On/Off
1
Board
Test to Clear Value
Any
test tone-clock UUC sh r 1
OFF
3
OFF
test tone-clock UUC
ON
test tone-clock UUC sh r 10
test tone-clock UUC sh
OFF
test tone-clock UUC sh
8-1177.