Avaya S8700 Maintenance Manual page 685

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

XXX-BD (Common Port Circuit Pack)
Technician-Demand Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Audit test (#50), you may also clear errors generated from other tests in the
testing sequence.
Order of Investigation
NPE Audit test (#50)
Ringing Application test (#51) (a)
Control Channel Loop-Around test (#52)
SAKI Sanity test (#53) (b)
Neon test (#220) (c)
1.
D = Destructive; ND = Nondestructive
Notes;
a. Only applicable to Analog Line circuit packs.
b. The SAKI Sanity test is run in the long test sequence for the Tone-Clock
circuit packs (TN768, TN780) only. The test is run on other circuit packs
only when they are reset via the reset board command.
c. Only applicable to TN746 and TN769 Analog Line circuit packs.
555-233-142
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
Issue 1 May 2002
Reset Board
1
Sequence
D/ND
ND
ND
ND
D
ND
8-1381