TIE-DS1 (DS1 Tie Trunk)
Table 8-489. Test #136 DS1 Tie Trunk Seizure Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is active but the port is idle (no calls), check the error log
3. If the port status is idle, retry the command at 1-minute intervals up to 5
1004
ABORT
Far end is seizing the trunk while the test is ongoing. A glare situation is
detected. Current test is designed to be aborted.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is idle, retry the command at 1-minute intervals up to 5
1005
ABORT
Test failed due to incompatible configuration administered in trunk group form.
1. Verify the following fields on the trunk group administration screen:
2. If the trunk has been administered using the above information, then this
1018
ABORT
The test was disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the Maintenance Test field on the 'Trunk Administration'
2. Repeat the test.
555-233-142
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
for error type 1025 (see the error log table for a description of this error and
required actions). The port may be locked up.
times.
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
times.
a. Is trunk direction incoming only?
b. Is trunk outgoing type either automatic or immediate-start?
th
c. Is trunk the 24
port of the DS1 Interface circuit pack while common
control channel signaling is specified?
test should abort.
screen is set to 'n.' To enable the test, change the trunk administration and
enter 'y' into the Maintenance Test field.
Continued on next page
Issue 1 May 2002
8-1149