Avaya S8700 Maintenance Manual page 70

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Port Diagnostic test (#35), you may also clear errors generated from other tests in
the testing sequence.
Table 8-328. System Technician-Demanded Tests: MET-LINE
Order of Investigation
NPE Crosstalk test (#6)
Port Diagnostic test (#35)
MFAT Electronic Power Feed test (#56)
Hybrid Circuit and Conference Circuit test (#57)
Station Lamp Update test (#60)
Station Audits test (#61)
Ringer Update test (#62)
1.
D = Destructive, ND = Nondestructive
8-766
Issue 1 May 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
Continued on next page
555-233-142
1
D/ND
ND
ND
ND
ND
ND
ND
ND

Advertisement