Maintenance Object Repair Procedure
Table 8-354. Test #270 Clear Error Counters
Error
Test
Code
Result
Description / Recommendation
PASS
The message to clear the Maintenance/Test circuit pack's counter for Background
Maintenance Failures has been sent.
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test analog port maintenance software
and call processing agree on the on-/off-hook status of the Maintenance/Test
analog port.
Table 8-355. Test #566 Hook State Inquiry
Error
Test
Code
Result
Description / Recommendation
1
ABORT
Switch hook audit timed out. No response was received from the circuit pack
for information about the switch hook state.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, replace the circuit pack and repeat the test.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
Any
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to fail reset the circuit pack via the busyout board
3. Retry the command at 1-minute intervals up to 3 times.
PASS
Call processing and Maintenance/Test analog port maintenance software
agree on the Maintenance/Test analog port hook state.
8-828
Issue 1 May 2002
UUCSS, reset board UUCSS, release board UUCSS command
sequence.