Avaya S8700 Maintenance Manual page 294

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Station Present Test (or Ringing Application Test)
(#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether the terminal equipment is
connected to the port. The test may cause some terminal equipment to ring
briefly during daily maintenance. If this ringing disturbs the customer or the
terminal equipment, disable it via the Tests field on the change station form.
However, on some software releases, Test #35 is disabled.
Table 8-420. Test #48 Station Present Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port UUCSSpp command to determine
the station extension. Use the status station command to determine the
service state of the port. If the service state indicates that the port is in use.
Wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test, and the test was aborted.
Use the display port UUCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the service state indicates that the port is in use. Wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1008
ABORT
Could not allocate a ringing circuit. Either every ringing circuit is in use, or the
ringing generator is either defective or incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log. If
1018
ABORT
The test has been disabled by administration. The default for the
on the change station form is
this station (this may be due to the brief ringing disturbance that this test may
cause).
1. To enable the test for the particular analog station being tested, enter
8-990
Issue 1 May 2002
an ABORT 1008 occurs for this test on other circuit packs as well, then the
ringing generator may be defective or incorrectly wired (see errors for
RING-GEN). If it does not occur on other ports, then all four ring phases
are in use.
change station extension and set the
station form to
y
.
y
. Determine why this field has been set to
field on the change
Test?
Continued on next page
field
Test
n
on