Maintenance Object Repair Procedure
Table 8-385. Test #7 Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1020
ABORT
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack. Even though wideband calls do not use the
PASS
The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated using other port tests and examining
terminal adapter or external wiring.
8-912
Issue 1 May 2002
and attempt to diagnose the already existing error.
conferencing feature on the NPE, this failure indicates problems with the
circuit pack hardware.
Continued on next page
555-233-142