Avaya S8700 Maintenance Manual page 433

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

TDM-CLK (TDM Bus Clock)
Table 8-481. Test #148 TDM bus Clock Circuit Status Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
65
FAIL
The tone-clock is currently not able to lock on to the current synchronization
reference. If this tone-clock is in the master port networK:
1. Examine the error log for any DS1-BD, SYNC or other TDM-CLK errors
2. Run this test again via the test tone-clock UUC command.
3. Examine the DS1 measurements to determine whether the facility is
4. Administer a new synchronization reference.
5. Replace the DS1 board currently supplying the reference.
If this tone-clock is in the slave port networK:
1. Examine the error log for any SYNC or TDM-CLK errors.
2. Run this test again via the test tone-clock UUC command.
66
FAIL
There is an on-board failure of TDM clock hardware.
1. Use test tone UUCSS long to resolve the problem. The long test resets
2. If the test passes and the alarm does not resolve, retest (test tone UUCSS
3. If the test passes, terminate the repair process. If it fails, replace the circuit
PASS
TDM bus Clock Circuit Status is sane. There are no clock-detection circuit
problems on the Tone-Clock circuit pack.
555-233-142
and resolve as applicable.
healthy.
the board and is required to reload on-board RAM associated with the
TN2182"s DSPs. The effect is that tone detectors are taken out of service
momentarily and tones are removed from the TDM bus for about 10
seconds. This means that no dial tone or touch tones are available during
this interval. It probably will not affect calls in progress, but could cause a
call origination to abort or a user will not get dial tone when going off hook.
long clear).
pack at the customer's convenience.
Continued on next page
Issue 1 May 2002
8-1129