RANL-STA (Remote Analog Line (Station) Port
Table 8-420. Test #48 Station Present Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The terminal equipment is not connected to the circuit pack. Some terminal
equipment, such as modems, may fail even when connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If present,
3. Check all of the wiring between the station equipment and the switch.
4. If the test still fails, the set may be defective. Check the set and replace it,
5. Some terminal equipment could fail even when it is connected properly. If
PASS
The station is connected properly. This test may also pass if no terminal
equipment is connected and the terminal is located very far from the switch.
Investigate user-reported troubles on this port by using other port tests,
examining station wiring, or examining the station.
555-233-142
see
''RING-GEN'' on page
Then, run the test again.
if necessary.
so, disable the test using the change station extension command (enter
into the
field). Note that this action also disables Test #35 on this
n
Test
port.
8-1008.