OPS-LINE (DS1 Off-Premises Station Line)
Table 8-368. Test #312 DS1 OPS Switchhook Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
The test was aborted because response to the test was not received within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test aborts with error code 2000 again, run short test sequence on
2012
ABORT
The test was aborted due to a system error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
Internal system error.
1. Look for DS1-BD/UDS1-BD errors in the Hardware Error Log. If present,
2. If a channel multiplexer is used as the remote DS1 endpoint to which the
3. Retry the command at 1-minute intervals up to 5 times.
PASS
The station hook states in both switch software and DS1 Interface circuit pack
are consistent.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
2012
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
555-233-142
the associated DS1-BD or UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting with error code 2000,
hyperactivity on the board or facility is indicated. In this case, the
hyperactivity problem should be dealt with first.
see
''DS1-BD (DS1 Interface Circuit Pack)'' on page
station connects, refer to the multiplexer vendor's maintenance document
for diagnosis.
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
8-456.