PDMODULE (Processor Data Module) TDMODULE
(Trunk Data Module)
Table 8-381. Test #175 Data Module Internal Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
2. If either list config or display port indicate that the port is not a TTI port,
2005
ABORT
The handshake between the Maintenance/Test digital port and the Data
Module failed.
1. Look for M/T-DIG errors in the Error Log. If present, see
2. If test still aborts on retry, check physical connection of data module under
3. If the test still aborts, replace the Data Module.
2312
ABORT
The loop-around test did not complete, failed to receive loop-back data.
1. Check for M/T-DIG error in the Error Log. If present, see
2. Retry the test, if still aborts, replace the Data Module.
3. If the test aborts again, replace the Digital Line circuit pack.
2313
ABORT
The Maintenance/Test digital port allocated for this test did not respond to
downlinked message.
1. Look for M/T-DIG errors in the Error Log. If present, see
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort, replace the MTB.
2314
ABORT
Data Module did not respond to downlinked message.
1. Check the wiring of the Data Module under test.
2. Verify that the Data Module is powered (power LED on).
3. Make sure the switches are on NORM, OFF (between REM_LP and LOC_
4. If the test still aborts, replace the Date Module.
5. If the same abort code appears, replace the Digital Line circuit pack that is
555-233-142
(the display shows that the port is a TTI port) or the list config command
(the display shows a "t" for the port).
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct for the test, and no action is necessary.
(Maintenance/Test Digital
test. Make sure the switches are on NORM, OFF (between REM_LP and
LOC_LP), 9600, and ASYN.
(Maintenance/Test Digital
(Maintenance/Test Digital
LP), 9600, and ASYN.
connected to the Data Module.
Port)''.
Port)''.
Port)''.
Continued on next page
Issue 1 May 2002
''M/T-DIG
''M/T-DIG
''M/T-DIG
8-899