M/T-DIG (Maintenance/Test Digital Port)
Table 8-358. Test #13 Digital Port Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
4. If the test continues to abort, escalate the problem.
1004
ABORT
The port was seized by a valid ISDN-PRI test call. Use the list isdn-testcall
command to determine which call is using the port (from the M/T Port column).
Either wait for the test call to complete (as indicated in the
Duration
isdn-testcall grp/mem command, where grp/mem is determined from the
B-channel
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the test at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
7
FAIL
Conference test failed on the primary information channel. In most cases, the
user may not notice a disruption in service.
1. Run the circuit pack tests to check the Tone Generator circuit pack and the
2. Resolve any problems that are detected on the Tone Generator circuit pack
3. If the Tone Generator and Tone Detector circuit packs are functioning
555-233-142
times.
fields of the above display), or abort the test call with the clear
field of the above display.
Tone Detector circuit pack via the test board UUCSS command.
or Tone Detector circuit pack.
properly, and the test still fails, replace the Maintenance/Test circuit pack.